PRODUCT LINE DESCRIPTION

Mirion designed a detector assembly based on 3’’x2’’ NaI(Tl) scintillation detector coupled to a photomultiplier tube specifically developed to perform 16N monitoring under severe environmental conditions. The SGLM 20XK (with or without shielding) is a non-intrusive system, providing fast measurements and minimizing the need of taking frequent samples for laboratory analysis. The estimation of the leak rate is then given by either a LPU or LPDU that processes the signal coming from the detector.

  • Leak rate: 6 to 31,700 GPD (1 to 5,000 l/h)
  • Radiation detected: 0.2 to 7.65 MeV
  • 1,024 channel analysis
  • Spectrum stabilization against drifting
  • MTBF: 20,000 hours

 

Show Product Comparison Table

Product Family Comparison

RangeQualificationDetectorExample of application
SGLM 201K
SGLM 202K
Measurement:
1 to 5000l/h
6 to 31700 GPD
1E QualifiedNaI , 3" x 2"  (with or without lead shielding)Main steam line monitoring
Extreme T°:
-5°C to 55°C
+23°F to +131°F
TID:
100 Gy
104 rad